Absolute angular rotation rate measurements with sensitivity better than prad/s would be beneficial for fundamental science investigations. In this regard, large frame Earth based ring laser gyroscopes are top instrumentation as far as bandwidth, long-term operation, and sensitivity are concerned. Here, we demonstrate that the GINGERINO active-ring laser upper limiting noise is close to 2×10-15 rad/s for ∼2×105 s of integration time, as estimated by the Allan deviation evaluated in a differential measurement scheme. This result is more than a factor of 10 better than the theoretical prediction so far accounted for ideal ring lasers shot-noise with the two beams counterpropagating inside the cavity considered as two independent propagating modes. This feature is related to the peculiarity of real ring laser system dynamics that causes phase crosstalking among the two counterpropagating modes. In this context, the independent beam model is, then, not applicable, and the measured noise limit falls below the expected one.

Noise Level of a Ring Laser Gyroscope in the Femto-Rad/s Range

Vitali D.
Ultimo
2024-01-01

Abstract

Absolute angular rotation rate measurements with sensitivity better than prad/s would be beneficial for fundamental science investigations. In this regard, large frame Earth based ring laser gyroscopes are top instrumentation as far as bandwidth, long-term operation, and sensitivity are concerned. Here, we demonstrate that the GINGERINO active-ring laser upper limiting noise is close to 2×10-15 rad/s for ∼2×105 s of integration time, as estimated by the Allan deviation evaluated in a differential measurement scheme. This result is more than a factor of 10 better than the theoretical prediction so far accounted for ideal ring lasers shot-noise with the two beams counterpropagating inside the cavity considered as two independent propagating modes. This feature is related to the peculiarity of real ring laser system dynamics that causes phase crosstalking among the two counterpropagating modes. In this context, the independent beam model is, then, not applicable, and the measured noise limit falls below the expected one.
2024
262
File in questo prodotto:
File Dimensione Formato  
published-PRL2024.pdf

solo gestori di archivio

Tipologia: Versione Editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 910.11 kB
Formato Adobe PDF
910.11 kB Adobe PDF   Visualizza/Apri   Richiedi una copia
2301.01386v2.pdf

accesso aperto

Tipologia: Documento in Post-print
Licenza: DRM non definito
Dimensione 690.29 kB
Formato Adobe PDF
690.29 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/483424
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? 4
social impact