: One of the major current societal challenges concerns the reuse of waste materials and valuable substances to mitigate the environmental impact of human activities, which has led to the increasing release of pollutants, from plastics to pharmaceuticals. In this study, we report a simple recycling strategy for surgical masks to obtain an activated carbon-like material, suitable for the solid-phase extraction (SPE) of Phthalic acid esters (PAEss) from plastic bottled water. The sorbent was produced by high-temperature calcination after sulfuric acid treatment to enhance the thermal stability of polypropylene. The sorbent was characterized by thermal analysis, Raman spectroscopy, FTIR and scanning electron microscopy. SPE was used to preconcentrate the analytes, and the main parameters affecting the extraction, such as pH, sorbent amount, organic modifier percentage, ionic strength and elution volume, were optimized. PAEs were determined by UHPLC-PDA under gradient elution. The developed method was linear in the range 0.25-1000 ng/mL, with LOQs between 0.25 and 0.10 ng/mL and LODs between 0.008 and 0.003 ng/mL. Recovery ranged from 95.9 to 104.7%, the precision expressed as RSD% was below 7.32, and the accuracy expressed as BIAS% ranged from -5.75 to 5.93. The proposed approach provides a simple and low-cost valorization route for PPE waste, while enabling reliable PAEs analysis in drinking water.

Efficient Valorization of Waste Surgical Masks for the Production of Activated Carbon-like Sorbent and Its Application in Solid-Phase Extraction and UHPLC-PDA Analysis of Phthalates in Water

Leonardo Sbrascini;Francesco Nobili;
2026-01-01

Abstract

: One of the major current societal challenges concerns the reuse of waste materials and valuable substances to mitigate the environmental impact of human activities, which has led to the increasing release of pollutants, from plastics to pharmaceuticals. In this study, we report a simple recycling strategy for surgical masks to obtain an activated carbon-like material, suitable for the solid-phase extraction (SPE) of Phthalic acid esters (PAEss) from plastic bottled water. The sorbent was produced by high-temperature calcination after sulfuric acid treatment to enhance the thermal stability of polypropylene. The sorbent was characterized by thermal analysis, Raman spectroscopy, FTIR and scanning electron microscopy. SPE was used to preconcentrate the analytes, and the main parameters affecting the extraction, such as pH, sorbent amount, organic modifier percentage, ionic strength and elution volume, were optimized. PAEs were determined by UHPLC-PDA under gradient elution. The developed method was linear in the range 0.25-1000 ng/mL, with LOQs between 0.25 and 0.10 ng/mL and LODs between 0.008 and 0.003 ng/mL. Recovery ranged from 95.9 to 104.7%, the precision expressed as RSD% was below 7.32, and the accuracy expressed as BIAS% ranged from -5.75 to 5.93. The proposed approach provides a simple and low-cost valorization route for PPE waste, while enabling reliable PAEs analysis in drinking water.
2026
PAEs determination
UHPLC-PDA
characterization
sample preparation
surgical mask upcycling
waste valorization
262
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/503846
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 0
social impact