Background Many studies consider the contamination of dental unit waterlines (DUWLs), but few of them have studied the possible presence of antibiotic resistant Pseudomonas aeruginosa in the DUWLs. Aims Investigation of the presence of P. aeruginosa and Pseudomonas spp. strains in DUWLs and evaluation of their resistance to six antibiotics (ceftazidime, netilmicin, piperacillin/tazobactam, meropenem, levofloxacin, colistin sulfate) at a public dental clinic in Milan, Italy. Results Dental units were contaminated by P. aeruginosa with loads of 2-1,000 CFU/L and were mainly located on the mezzanine floor, with a range of 46-54%, while Pseudomonas spp. were primarily found on the first and second floors, ranging from 50 to 91%. P. aeruginosa was antibiotic resistant in 30% of the strains tested, andPseudomonas spp. in 31.8% . Cold water from controls was also contaminated by these microorganisms. Conclusion Monitoring antibiotic resistance in the water and adopting disinfection procedures on DUs are suggested within the Water Safety Plan.

Dental unit water content and antibiotic resistance of Pseudomonas aeruginosa and Pseudomonas species: a case study

Grappasonni I.;
2022-01-01

Abstract

Background Many studies consider the contamination of dental unit waterlines (DUWLs), but few of them have studied the possible presence of antibiotic resistant Pseudomonas aeruginosa in the DUWLs. Aims Investigation of the presence of P. aeruginosa and Pseudomonas spp. strains in DUWLs and evaluation of their resistance to six antibiotics (ceftazidime, netilmicin, piperacillin/tazobactam, meropenem, levofloxacin, colistin sulfate) at a public dental clinic in Milan, Italy. Results Dental units were contaminated by P. aeruginosa with loads of 2-1,000 CFU/L and were mainly located on the mezzanine floor, with a range of 46-54%, while Pseudomonas spp. were primarily found on the first and second floors, ranging from 50 to 91%. P. aeruginosa was antibiotic resistant in 30% of the strains tested, andPseudomonas spp. in 31.8% . Cold water from controls was also contaminated by these microorganisms. Conclusion Monitoring antibiotic resistance in the water and adopting disinfection procedures on DUs are suggested within the Water Safety Plan.
2022
262
File in questo prodotto:
File Dimensione Formato  
Dental unit water content and antibiotic resistance of Pseudomonas aeruginosa and Pseudomonas species a case study.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: PUBBLICO - Creative Commons
Dimensione 2.16 MB
Formato Adobe PDF
2.16 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/471763
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact