Graphene quality indicators obtained by Raman spectroscopy have been correlated to the structural changes of the graphene/germanium interface as a function of in-vacuum thermal annealing. Specifically, it was found that graphene becomes markedly defective at 650 degrees C. By combining scanning tunneling microscopy, X-ray photo-electron spectroscopy and near edge X-ray absorption fine structure spectroscopy, we concluded that these de-fects are due to the release of H-2 gas trapped at the graphene/germanium interface. The H-2 gas was produced following the transition from the as-grown hydrogen-termination of the Ge(1 1 0) surface to the emergence of surface reconstructions in the substrate. Interestingly, a complete self-healing process was observed in graphene upon annealing at 800 degrees C. The identified subtle interplay between the microscopic changes occurring at the graphene/germanium interface and graphene's defect density is integral to advancing the understanding of graphene growth directly on semiconductor substrates, controlled 2D-3D heterogeneous materials interfacing and integrated fabrication technology.

Tracking interfacial changes of graphene/Ge(110) during in-vacuum annealing

Gunnella, R;
2022-01-01

Abstract

Graphene quality indicators obtained by Raman spectroscopy have been correlated to the structural changes of the graphene/germanium interface as a function of in-vacuum thermal annealing. Specifically, it was found that graphene becomes markedly defective at 650 degrees C. By combining scanning tunneling microscopy, X-ray photo-electron spectroscopy and near edge X-ray absorption fine structure spectroscopy, we concluded that these de-fects are due to the release of H-2 gas trapped at the graphene/germanium interface. The H-2 gas was produced following the transition from the as-grown hydrogen-termination of the Ge(1 1 0) surface to the emergence of surface reconstructions in the substrate. Interestingly, a complete self-healing process was observed in graphene upon annealing at 800 degrees C. The identified subtle interplay between the microscopic changes occurring at the graphene/germanium interface and graphene's defect density is integral to advancing the understanding of graphene growth directly on semiconductor substrates, controlled 2D-3D heterogeneous materials interfacing and integrated fabrication technology.
2022
File in questo prodotto:
File Dimensione Formato  
1-s2.0-S0169433222018256-main.pdf

solo gestori di archivio

Tipologia: Versione Editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 10.01 MB
Formato Adobe PDF
10.01 MB Adobe PDF   Visualizza/Apri   Richiedi una copia
Tracking interfacial changes of graphene-Ge110 during in-vacuum annealing _ pre print.pdf

accesso aperto

Tipologia: Documento in Pre-print
Licenza: DRM non definito
Dimensione 1.46 MB
Formato Adobe PDF
1.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/467455
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2