Problem statement: Zolpidem is a non-benzodiazepine hypnotic agent currently used in human medicine. In contrast to benzodiazepines, zolpidem preferentially binds with the GABAA complex πvariant 1 receptors while poorly interacting with the other πvariant receptor complexes. Recent studies have suggested that ZP may be used to initiate sedation and diminish severe anxiety responses in dogs. The aim of the present study is to develop and validate a new HPLC-FL based method to quantify zolpidem in canine plasma. Approach: Several parameters both in the extraction and in the detection method were evaluated. The applicability of the method was determined by administering zolpidem to one dog. Results: The final mobile phase was acetonitrile: KH2PO4 (15 mM; pH 6.0) 40:60 v/v, with a flow rate of 1 mL min-1 and excitation and emission wave lengths of 254 and 400 nm, respectively. The best extraction solvent was CH2Cl2:Et2O (3:7 v/v), this gave recoveries ranging from 83-95%. The limit of quantification was 1 ng mL-1. The chromatographic runs were specific with no interfering peaks at the retention times of the analyte. The other validation parameters were in agreement with the EMEA. Conclusion/Recommendations: This method (extraction, separation and applied techniques) is simple and effective. This technique may have applications for pharmacokinetic or toxicological studies. © 2012 Science Publications.

Quantification of zolpidem in canine plasma

Gavazza, Alessandra;
2012-01-01

Abstract

Problem statement: Zolpidem is a non-benzodiazepine hypnotic agent currently used in human medicine. In contrast to benzodiazepines, zolpidem preferentially binds with the GABAA complex πvariant 1 receptors while poorly interacting with the other πvariant receptor complexes. Recent studies have suggested that ZP may be used to initiate sedation and diminish severe anxiety responses in dogs. The aim of the present study is to develop and validate a new HPLC-FL based method to quantify zolpidem in canine plasma. Approach: Several parameters both in the extraction and in the detection method were evaluated. The applicability of the method was determined by administering zolpidem to one dog. Results: The final mobile phase was acetonitrile: KH2PO4 (15 mM; pH 6.0) 40:60 v/v, with a flow rate of 1 mL min-1 and excitation and emission wave lengths of 254 and 400 nm, respectively. The best extraction solvent was CH2Cl2:Et2O (3:7 v/v), this gave recoveries ranging from 83-95%. The limit of quantification was 1 ng mL-1. The chromatographic runs were specific with no interfering peaks at the retention times of the analyte. The other validation parameters were in agreement with the EMEA. Conclusion/Recommendations: This method (extraction, separation and applied techniques) is simple and effective. This technique may have applications for pharmacokinetic or toxicological studies. © 2012 Science Publications.
2012
File in questo prodotto:
File Dimensione Formato  
C 29 - ajavs 2012.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: PUBBLICO - Creative Commons
Dimensione 129.98 kB
Formato Adobe PDF
129.98 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/454044
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? ND
social impact