A hand-made, radiolucent, custom-designed device having a mobile and a non-mobile platforms was used to objectively quantify the in vivo cranial tibial translation, in order to assess the functional status of cranial-cruciate-ligament (CrCL) in dogs. The hypothesis was that changes in CrCL integrity would result in detectable changes in tibial translation. To validate the diagnostic method, data from injured (PA, n = 32), contralateral (CO, n = 32) and healthy stifles (HE, n = 32) were compared. Normalized tibial translation (ΔN) of each stifle was measured in medio-lateral radiographic projection obtained before and during standard thrust force application, in PA (43.59±12.97%), CO (20.32±6.69%) and HE (12.22±3.77%). Comparing PA with HE and CO (ΔN cut-off value: 29.73%), diagnosis could be issued with very high probability. Comparing HE with CO (ΔN cut-off value: 14.80%), high performance was obtained. The translator device could be a useful tool to objectively quantify the in vivo tibial translation in dogs with CrCL rupture, before surgery and during post-operatory follow-up.

Evaluation of cranial tibial translation in dogs: Diagnostic accuracy of radiographic method using a simple device

Tambella, Adolfo Maria;Attili, Anna Rita;Vullo, Cecilia;Martin, Stefano
2020-01-01

Abstract

A hand-made, radiolucent, custom-designed device having a mobile and a non-mobile platforms was used to objectively quantify the in vivo cranial tibial translation, in order to assess the functional status of cranial-cruciate-ligament (CrCL) in dogs. The hypothesis was that changes in CrCL integrity would result in detectable changes in tibial translation. To validate the diagnostic method, data from injured (PA, n = 32), contralateral (CO, n = 32) and healthy stifles (HE, n = 32) were compared. Normalized tibial translation (ΔN) of each stifle was measured in medio-lateral radiographic projection obtained before and during standard thrust force application, in PA (43.59±12.97%), CO (20.32±6.69%) and HE (12.22±3.77%). Comparing PA with HE and CO (ΔN cut-off value: 29.73%), diagnosis could be issued with very high probability. Comparing HE with CO (ΔN cut-off value: 14.80%), high performance was obtained. The translator device could be a useful tool to objectively quantify the in vivo tibial translation in dogs with CrCL rupture, before surgery and during post-operatory follow-up.
2020
262
File in questo prodotto:
File Dimensione Formato  
journal.pone.0228621.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: PUBBLICO - Creative Commons
Dimensione 1.2 MB
Formato Adobe PDF
1.2 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/433490
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact