A hand-made, radiolucent, custom-designed device having a mobile and a non-mobile platforms was used to objectively quantify the in vivo cranial tibial translation, in order to assess the functional status of cranial-cruciate-ligament (CrCL) in dogs. The hypothesis was that changes in CrCL integrity would result in detectable changes in tibial translation. To validate the diagnostic method, data from injured (PA, n = 32), contralateral (CO, n = 32) and healthy stifles (HE, n = 32) were compared. Normalized tibial translation (ΔN) of each stifle was measured in medio-lateral radiographic projection obtained before and during standard thrust force application, in PA (43.59±12.97%), CO (20.32±6.69%) and HE (12.22±3.77%). Comparing PA with HE and CO (ΔN cut-off value: 29.73%), diagnosis could be issued with very high probability. Comparing HE with CO (ΔN cut-off value: 14.80%), high performance was obtained. The translator device could be a useful tool to objectively quantify the in vivo tibial translation in dogs with CrCL rupture, before surgery and during post-operatory follow-up.
Evaluation of cranial tibial translation in dogs: Diagnostic accuracy of radiographic method using a simple device
Tambella, Adolfo Maria;Attili, Anna Rita;Vullo, Cecilia;Martin, Stefano
2020-01-01
Abstract
A hand-made, radiolucent, custom-designed device having a mobile and a non-mobile platforms was used to objectively quantify the in vivo cranial tibial translation, in order to assess the functional status of cranial-cruciate-ligament (CrCL) in dogs. The hypothesis was that changes in CrCL integrity would result in detectable changes in tibial translation. To validate the diagnostic method, data from injured (PA, n = 32), contralateral (CO, n = 32) and healthy stifles (HE, n = 32) were compared. Normalized tibial translation (ΔN) of each stifle was measured in medio-lateral radiographic projection obtained before and during standard thrust force application, in PA (43.59±12.97%), CO (20.32±6.69%) and HE (12.22±3.77%). Comparing PA with HE and CO (ΔN cut-off value: 29.73%), diagnosis could be issued with very high probability. Comparing HE with CO (ΔN cut-off value: 14.80%), high performance was obtained. The translator device could be a useful tool to objectively quantify the in vivo tibial translation in dogs with CrCL rupture, before surgery and during post-operatory follow-up.File | Dimensione | Formato | |
---|---|---|---|
journal.pone.0228621.pdf
accesso aperto
Tipologia:
Versione Editoriale
Licenza:
PUBBLICO - Creative Commons
Dimensione
1.2 MB
Formato
Adobe PDF
|
1.2 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.