Nowadays, there is much experimental evidence that the mechanical properties of biological membranes affect membrane protein functions. A very convenient technique to study these properties on a spatial scale relevant to that of single proteins is represented by Atomic Force Spectroscopy (AFS). In this study we measured the force the AFM tip has to apply on a supported lipid bilayer to punch-through it as a function of different environmental parameters. We observed that this force is reduced when the lipid bilayer is in its phase transition region. We interpreted our results on the basis of thermodynamical considerations and we stressed their biological relevance. In particular, the reduced punch-through force in the phase transition region could be relevant for the function of membrane proteins which operates by conformational changes at the protein/lipid interface. We also suggest that the presence of a transmembrane voltage drop can affect the measured punch-through force.

What do we really measure in AFM punch-through experiments on supported lipid bilayers?

Di Cerbo, Alessandro;
2011-01-01

Abstract

Nowadays, there is much experimental evidence that the mechanical properties of biological membranes affect membrane protein functions. A very convenient technique to study these properties on a spatial scale relevant to that of single proteins is represented by Atomic Force Spectroscopy (AFS). In this study we measured the force the AFM tip has to apply on a supported lipid bilayer to punch-through it as a function of different environmental parameters. We observed that this force is reduced when the lipid bilayer is in its phase transition region. We interpreted our results on the basis of thermodynamical considerations and we stressed their biological relevance. In particular, the reduced punch-through force in the phase transition region could be relevant for the function of membrane proteins which operates by conformational changes at the protein/lipid interface. We also suggest that the presence of a transmembrane voltage drop can affect the measured punch-through force.
2011
File in questo prodotto:
File Dimensione Formato  
Soft Matter 2011.pdf

solo gestori di archivio

Tipologia: Versione Editoriale
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 449.44 kB
Formato Adobe PDF
449.44 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/431099
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 31
social impact