The contamination of wastewater with pesticides has been recognised as an area of increasing concern by the European Commission. Effluent from wastewater treatment plants have been identified as an important source of pesticides in the environment. An on-line high performance liquid chromatography- heated electrospray ionization tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of pesticides in effluent wastewaters. Currently available methods for pesticide analysis in wastewater samples are time-consuming and require complex clean-up steps. The main objective of this study was the development of a simple solid phase extraction (SPE) procedure for matrix removal and an on-line sample pre-concentration step to permit the detection of target analytes at μg/l concentration levels in wastewater samples. Wastewater (1 ml) was pre-concentrated on a C18 trapping column with a CTC autosampler and backflushed onto an analytical column (C8) with detection using triple quadrupole MS/MS. The MS method exploited mass resolution (0.6 – 0.15) to improve the signal/noise and detection limits for pesticides. This method was applied to the determination of methoxytriazine, chlorotriazines, chloroacetanilides, phenylurea and carbamate pesticides, with consistent linear calibration data within the target analyte concentrations of 1-10 μg/l. Using this method, simazine, atrazine, atrazine desethyl, prometon and diuron were determined in wastewater samples throughout County Cork, Ireland. Analyte conformation was carried out using high resolution mass spectrometry (Orbitrap XL).

Method for the Determination of Basic Pesticides in (ppb) Levels in Wastewater.

Giovanni Caprioli;Sauro Vittori;
2010-01-01

Abstract

The contamination of wastewater with pesticides has been recognised as an area of increasing concern by the European Commission. Effluent from wastewater treatment plants have been identified as an important source of pesticides in the environment. An on-line high performance liquid chromatography- heated electrospray ionization tandem mass spectrometric (LC-MS/MS) method was developed and validated for the determination of pesticides in effluent wastewaters. Currently available methods for pesticide analysis in wastewater samples are time-consuming and require complex clean-up steps. The main objective of this study was the development of a simple solid phase extraction (SPE) procedure for matrix removal and an on-line sample pre-concentration step to permit the detection of target analytes at μg/l concentration levels in wastewater samples. Wastewater (1 ml) was pre-concentrated on a C18 trapping column with a CTC autosampler and backflushed onto an analytical column (C8) with detection using triple quadrupole MS/MS. The MS method exploited mass resolution (0.6 – 0.15) to improve the signal/noise and detection limits for pesticides. This method was applied to the determination of methoxytriazine, chlorotriazines, chloroacetanilides, phenylurea and carbamate pesticides, with consistent linear calibration data within the target analyte concentrations of 1-10 μg/l. Using this method, simazine, atrazine, atrazine desethyl, prometon and diuron were determined in wastewater samples throughout County Cork, Ireland. Analyte conformation was carried out using high resolution mass spectrometry (Orbitrap XL).
2010
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/407273
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact