The purpose of this study was to describe and assess the feasibility of a new intra-articular approach in the treatment of cranial cruciate ligament deficiency in dogs using an artificial ligament and a new bone-anchor system. Twelve canine cadavers weighting 26 to 45 kg were used in this ex-vivo study. Special tibial and femoral screws, two helicoils, and a high resistance artificial fiber compose the implant. Surgery was performed using the mean cranio-lateral approach to the stifle joint. Helicoil and tibial screw, connected to the fiber, were inserted in the center of the tibial insertion area of the cranial cruciate ligament. The fiber was passed over-the-top, tensioned, and fixed to the femoral screw, previously inserted with the helicoil in the distal part of the femur. Surgery was completed in all the cases. Occasional problems found during the insertion of the helicoils and screws were resolved with simple procedures. Post-operative clinical assessment showed negative cranial drawer test, negative cranial tibial thrust, and normal range of motion. Radiographic evaluation showed an appropriate positioning of both tibial and femoral implants in all the cases. The results of the first surgical appraisal of this new technique are encouraging, although further studies are necessary to demonstrate the in vivo efficacy of this procedure.

Innovative, intra-articular, prosthetic technique for cranial cruciate ligament reconstruction in dogs: a cadaveric study

Martin, Stefano;Tambella, Adolfo Maria
2018-01-01

Abstract

The purpose of this study was to describe and assess the feasibility of a new intra-articular approach in the treatment of cranial cruciate ligament deficiency in dogs using an artificial ligament and a new bone-anchor system. Twelve canine cadavers weighting 26 to 45 kg were used in this ex-vivo study. Special tibial and femoral screws, two helicoils, and a high resistance artificial fiber compose the implant. Surgery was performed using the mean cranio-lateral approach to the stifle joint. Helicoil and tibial screw, connected to the fiber, were inserted in the center of the tibial insertion area of the cranial cruciate ligament. The fiber was passed over-the-top, tensioned, and fixed to the femoral screw, previously inserted with the helicoil in the distal part of the femur. Surgery was completed in all the cases. Occasional problems found during the insertion of the helicoils and screws were resolved with simple procedures. Post-operative clinical assessment showed negative cranial drawer test, negative cranial tibial thrust, and normal range of motion. Radiographic evaluation showed an appropriate positioning of both tibial and femoral implants in all the cases. The results of the first surgical appraisal of this new technique are encouraging, although further studies are necessary to demonstrate the in vivo efficacy of this procedure.
2018
File in questo prodotto:
File Dimensione Formato  
CrCL cadaveric study.pdf

accesso aperto

Tipologia: Versione Editoriale
Licenza: PUBBLICO - Creative Commons
Dimensione 2.83 MB
Formato Adobe PDF
2.83 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/406443
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact