An original method, based on the energy-dispersive X-ray diffraction, has been recently proposed as a possible laboratory tool to accomplish long time resolved investigation of the water content in a Proton Exchange Membrane Fuel Cell. However, this method has never been applied to a real working fuel cell. Therefore, a clear comprehension of its effectiveness in terms of relevant parameters such as time and space resolution, sensitivity and reproducibility has not yet been achieved. In this paper, all these aspects are discussed and clarified. In order to focus on the method overall effectiveness and on the extent of possible improvements, a basic experimental configuration for both the electrochemical station and the X-ray equipment has been set. The method is described with particular attention to its operating principle and to the evaluation of the errors introduced in data assessment. Finally, applications to some model experiments, in particular working states of the device, are provided and the obtained results are discussed.

Energy Dispersive X-ray Diffraction Applied to Laboratory Investigation on Proton Exchange Membrane Water Content in Working Fuel Cells

NOBILI, Francesco;
2012-01-01

Abstract

An original method, based on the energy-dispersive X-ray diffraction, has been recently proposed as a possible laboratory tool to accomplish long time resolved investigation of the water content in a Proton Exchange Membrane Fuel Cell. However, this method has never been applied to a real working fuel cell. Therefore, a clear comprehension of its effectiveness in terms of relevant parameters such as time and space resolution, sensitivity and reproducibility has not yet been achieved. In this paper, all these aspects are discussed and clarified. In order to focus on the method overall effectiveness and on the extent of possible improvements, a basic experimental configuration for both the electrochemical station and the X-ray equipment has been set. The method is described with particular attention to its operating principle and to the evaluation of the errors introduced in data assessment. Finally, applications to some model experiments, in particular working states of the device, are provided and the obtained results are discussed.
2012
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/244931
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact