Passive protection systems have proven to be efficient solutions for the seismic protection of both new and existing buildings. Recently an increasing attention is paid towards their use in external configurations, especially for existing structures since their lower interferences with both the structures to protect and the activities carried on within the buildings. Retrofit and seismic upgrading based on external dissipative elements, indeed, are very promising in postearthquake phases, making it possible a notable reduction of building downtime and impacts on users. This paper concerns the seismic retrofit of the Fazzini college, an existing r.c. frame building of the University of Camerino severely damaged during the 2016 Central Italy seismic sequence. The retrofit has been designed with an external passive system equipped with fluid viscous dampers aiming to prevent damage to both structural and non-structural components up to severe earthquakes.

BUILDING BACK BETTER: THE CASE STUDY OF THE FAZZINI COLLEGE

Gioiella, Laura
Primo
;
Micozzi, Fabio
Secondo
;
Ragni, Laura
Penultimo
;
Dall'Asta, Andrea
Ultimo
2023-01-01

Abstract

Passive protection systems have proven to be efficient solutions for the seismic protection of both new and existing buildings. Recently an increasing attention is paid towards their use in external configurations, especially for existing structures since their lower interferences with both the structures to protect and the activities carried on within the buildings. Retrofit and seismic upgrading based on external dissipative elements, indeed, are very promising in postearthquake phases, making it possible a notable reduction of building downtime and impacts on users. This paper concerns the seismic retrofit of the Fazzini college, an existing r.c. frame building of the University of Camerino severely damaged during the 2016 Central Italy seismic sequence. The retrofit has been designed with an external passive system equipped with fluid viscous dampers aiming to prevent damage to both structural and non-structural components up to severe earthquakes.
2023
fluid viscous dampers
damage control
external passive system
structure-non-structure interaction
273
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/496069
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact