Purpose Identify qualitative features and quantitative parameters of the iridocorneal angle in healthy cats using ultrasound biomicroscopy (UBM). Methods Eight cats for a total of 16 eyes, admitted at the Veterinary Teaching Hospital of the University of Camerino for routine procedures were included in this study. All cats included were free from ophthalmic diseases, had a normal intraocular pressure (IOP) pressure and did not undergo pharmacological therapy potentially affecting the IOP. Images and measurements were obtained from all cats using ACCUTOME PLUS UBM device after sedation and topical anesthesia. The following measurements were obtained: HICA (height iridocornel angle), DICA (depth iridocorneal angle), ICA (iridocorneal angle area) e HAC (height anterior chamber). All the data obtained by three sequential measurements from each eye were summarized in mean and standard deviation and subjected to omoscedasticity analysis using Cochrane test. Results In all cats, the UBM examination allowed a full evaluation of the cornea and the scleral corneal junction, the iris, the crystalline and the drainage angle. Mean HICA was 1.43 ± 0.15 mm (C=0.30, α=0.01), mean DICA was 3.05 ± 0.27 mm (C=0.14, α=0.01), mean ICA was 1.83 ± 0.28 mm2 (C=0.28, α=0.01), mean HAC was 3.47 ± 0.12 mm (C=0.24, α=0.01). Conclusion Despite the small sample size, measured data were statistically homogeneous in the population studied. UBM is an easy-to-use method that can be used to study the iridocorneal angle in cats. To the author knowledge, this study provided the first in vivo UBM evaluation in healthy cats.

Ultrasound biomicroscopy and evaluation of the feline iridocorneal angle

Cassarani, Maria Paola;Stroppa, Giulia;Tambella, Adolfo Maria
2017-01-01

Abstract

Purpose Identify qualitative features and quantitative parameters of the iridocorneal angle in healthy cats using ultrasound biomicroscopy (UBM). Methods Eight cats for a total of 16 eyes, admitted at the Veterinary Teaching Hospital of the University of Camerino for routine procedures were included in this study. All cats included were free from ophthalmic diseases, had a normal intraocular pressure (IOP) pressure and did not undergo pharmacological therapy potentially affecting the IOP. Images and measurements were obtained from all cats using ACCUTOME PLUS UBM device after sedation and topical anesthesia. The following measurements were obtained: HICA (height iridocornel angle), DICA (depth iridocorneal angle), ICA (iridocorneal angle area) e HAC (height anterior chamber). All the data obtained by three sequential measurements from each eye were summarized in mean and standard deviation and subjected to omoscedasticity analysis using Cochrane test. Results In all cats, the UBM examination allowed a full evaluation of the cornea and the scleral corneal junction, the iris, the crystalline and the drainage angle. Mean HICA was 1.43 ± 0.15 mm (C=0.30, α=0.01), mean DICA was 3.05 ± 0.27 mm (C=0.14, α=0.01), mean ICA was 1.83 ± 0.28 mm2 (C=0.28, α=0.01), mean HAC was 3.47 ± 0.12 mm (C=0.24, α=0.01). Conclusion Despite the small sample size, measured data were statistically homogeneous in the population studied. UBM is an easy-to-use method that can be used to study the iridocorneal angle in cats. To the author knowledge, this study provided the first in vivo UBM evaluation in healthy cats.
2017
European Society of veterinary Ophtalmology Meeting 2017
274
File in questo prodotto:
File Dimensione Formato  
ubm feline esvo 2017.pdf

solo gestori di archivio

Tipologia: Documento in Post-print
Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 548.68 kB
Formato Adobe PDF
548.68 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/406102
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact