It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2 K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2 . Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature. Keywords: Green wall; Experimental building; Comparative analysis; Summer performance.

Testing the performance of a green wall system on an experimental building in the summer

COCCI GRIFONI, ROBERTA;
2013-01-01

Abstract

It is known that a green wall brings some advantages to a building. It constitutes a barrier against solar radiation, thus decreasing and delaying the incoming heat flux. The aim of this study is to quantify such advantages through analytical comparison between two facades, a vegetal facade and a conventional facade. Both were highly insulated (U-value = 0.3 W/m2 K) and installed facing south on the same building in the central territory of Spain. In order to compare their thermal trend, a series of sensors were used to register superficial and indoor air temperature. The work was carried out between 17th August 2012 and 1st October 2012, with a temperature range of 12°C-36°C and a maximum horizontal radiation of 1020 W/m2 . Results show that the indoor temperature of the green wall module was lower than the other. Besides, comparing superficial outdoor and indoor temperatures of the two walls to outdoor air temperatures, it was noticed that, due to the shading plants, the green wall superficial temperature was 5 °C lower on the facade, while the bare wall temperature was 15 °C higher. The living wall module temperature was 1.6 °C lower than the outdoor, while the values of the conventional one were similar to the outdoor air temperature. Keywords: Green wall; Experimental building; Comparative analysis; Summer performance.
2013
9783816790549
273
File in questo prodotto:
File Dimensione Formato  
testing_the_performance_of_a_green_wall_system_on_an_experimental_building_in_the_summer.pdf

solo gestori di archivio

Licenza: NON PUBBLICO - Accesso privato/ristretto
Dimensione 4.82 MB
Formato Adobe PDF
4.82 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/312781
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact