This communication suggests how the S/N ratio in the electrochemical determination of Captopril in urine samples can be simply improved. The proposed method involves unselective degradation of the proteins present in urine samples by refrigerating them down to −196°C. The separation is accomplished via ultracentrifugation at room temperature in such a way that very little manipulation of the sample occurs. This physical method is a useful tool for reducing background noise due to adsorbable products and for handling the sample as little as possible.

Cleaning up procedure for captopril determination in urine samples by non intrusive method

PASSAMONTI, Paolo;
1995-01-01

Abstract

This communication suggests how the S/N ratio in the electrochemical determination of Captopril in urine samples can be simply improved. The proposed method involves unselective degradation of the proteins present in urine samples by refrigerating them down to −196°C. The separation is accomplished via ultracentrifugation at room temperature in such a way that very little manipulation of the sample occurs. This physical method is a useful tool for reducing background noise due to adsorbable products and for handling the sample as little as possible.
1995
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11581/249347
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact